Case Study:
Transmission Durability
Client
UK automotive consultancy
Objective
Perform shift fork stress analysis for durability.
Scope
- Application of worst case loading on the shift fork
- Maintaining proper contact between friction pads of shift fork and synchronizer
- Perform non-linear static analysis of the shift fork assembly
- Perform durability analysis
Success
Minimum fatigue safety factors improved to 1.5